2. Fast installation — A typical Tri-Stack four fan
exhaust
system can be mounted on the roof – in less than two hours – with minimal rigging equipment. And when retrofitting existing
ventilation fans and
systems (typically installed while penthouses are being constructed), Tri-Stack eliminates the need for “temporary” exhaust systems. In addition to substantially lower installation costs, engineering costs are also reduced, as well as disruption of work schedules which can cause wasteful and expensive downtime.
3. Reduced horsepower motors — A new exhaust nozzle design maximizes system performance to provide increased airflow and efficiency while lowering horsepower requirements, thus further reducing energy consumption.
4. No protective penthouses — Without maintenance problems, there’s no need for expensive penthouses to protect maintenance personnel on the roof under adverse conditions. Instead, you can expect savings of several hundreds of
thousands of dollars in a typical installation.
5. Maintenance-free operation — Tri-Stack’s direct drive motors are virtually maintenance-free with typical lifetimes of 200,000 hours. There are no belts, pulleys, flex connectors, or spring vibration isolators to maintain, and the motors
are designed to operate continuously – without periodic maintenance – for years
under normal conditions.
6. Unique exhaust nozzle design — Tri-Stack
fume exhausters
incorporate computer designed, state-of-the-art exhaust nozzle designs that help lower resistance, increase flow and pressure, and increase stack outlet velocities to minimize bypass requirements. These characteristics work together to further reduce operating costs.
7. Special fan wheel design — Tri-Stack’s unique fan wheels are developed with Computer Aided Design (CAD) techniques. Efficient fan blade design helps lower horsepower requirements with subsequent energy reduction. In addition, non-stall characteristics permit use of variable frequency drives, further enhancing efficiency and reducing energy consumption.
8. No expensive silencers needed — Increased air flow vs. resistance efficiencies enable Tri-Stack
fume exhaust
systems to provide high performance at substantially lower noise levels–particularly in the lower octave bands–often eliminating the need for expensive inlet and/or outlet silencers.
9. Simple installation without roof curbs — Stack height of Tri-Stack systems is only about 60% of conventional
roof
stacks. Low profile design eliminates the need for spring isolation, inertia bases, flexible connections, guy wires (with associated pitch pocket roof leaks), or other expensive, time-consuming and maintenance intensive installation hardware and procedures.
10. 200,000 hour motor lifetimes — The direct drive motors in Tri-Stack
fume exhaust
systems are designed to operate continuously for years under normal conditions;
typical lifetimes are 200,000 hours.